ECG Helper
Get the heart rate from any strip at 25 or 50 mm/s, turn millimetres into milliseconds and millivolts, and check each wave against normal for a dog or cat. Tap along with the monitor for an instant rate, or load a photo of the strip and measure with two lines. Answer four questions to name the rhythm and see a drawn example, then get the steps and doses: lidocaine for ventricular tachycardia in mL, rate control for atrial fibrillation, the atropine test for slow rhythms, and tablets for the long term. With a picture guide, electrical axis, 24-hour recording reader, pacemaker checks and a report builder.
Before you begin: check the patient before the trace. Pulse, gum colour and blood pressure decide how urgent a rhythm is. A wide, slow rhythm is an escape rhythm and must not be suppressed.
Species and weight
Normal values change with the species. Doses and infusion rates are worked out for this weight.
What do you need?
Pick a tool. Your entries are kept when you switch between them.
Enter what you have. The result updates as you go.
Result
Updates with every change.
The result will appear here
Plan
Worked out
Next
What to tell the owner
Show the working
Result as text for the clinical notes
For veterinarians and veterinary nurses. The helper works from what you enter and cannot see the trace. It suggests the likely rhythm and does not replace reading the strip or a cardiologist. Check every dose, dilution and rate before giving it.
ECG guide
Quick answer
Heart rate from a strip is paper speed in mm/s times 60, divided by the R to R distance in mm. At 50 mm/s that is 600 divided by the number of big boxes between two R waves, and at 25 mm/s it is 300. Read every trace in the same order: rate, regularity, a P for every QRS and a QRS for every P, then QRS shape. Treat a wide, fast rhythm in a dog with lidocaine 2 mg/kg into the vein when the rate is over 180, runs over 30 seconds go above 160, the pulses are poor, beats land on T waves, or the shapes vary. Never give it to a slow, wide escape rhythm.
How to use the helper
- Pick the species. Enter the weight for any tool that gives a dose. Rabbits and ferrets get the rate, measuring, rhythm, picture, ruler, set-up and report tools.
- "Heart rate": choose big boxes, R to R in mm, a beat count, or tap along with the monitor or a stethoscope.
- "Photo ruler": load a photo of the strip, set the scale across 5 big boxes, then drag two lines to measure. The photo never leaves the device.
- "Measure the waves": enter widths and heights in mm. The helper converts to milliseconds and millivolts and checks each against normal.
- "Name the rhythm": answer four questions and tick anything else you see. It names the likely rhythm, draws an example and sends you to the right treatment tool. "Picture guide" shows a labelled drawing of 46 rhythms and wave changes.
- "By condition": pick the problem, such as high potassium, GDV, fluid around the heart or a fainting terrier, and see every ECG change to look for, drawn and labelled.
- "Wide and fast", "Narrow and fast" and "Slow rhythms and heart block" give the steps and doses in mg and mL.
- "Electrolytes and the ECG" links potassium and calcium to the trace. "Tablets for the long term" gives doses with tablet sizes and an owner sheet.
- "ECG report" collects your rate, rhythm, measurements and axis into one block of text for the record.
Rate and normal values
| Measure, lead II | Dog | Cat |
|---|---|---|
| Heart rate in the clinic | 70 to 160. Toy breeds to 180, puppies to 220, giant breeds 60 to 140 | 140 to 220 |
| P wave | Up to 40 ms (50 in giant breeds) and 0.4 mV | Up to 40 ms and 0.2 mV |
| PR interval | 60 to 130 ms | 50 to 90 ms |
| QRS width | Up to 50 ms (60 in large breeds) | Up to 40 ms |
| R wave height | Up to 2.5 mV (3.0 in large breeds) | Up to 0.9 mV |
| QT interval | 150 to 250 ms | 120 to 180 ms |
Rabbits run 130 to 325 a minute and ferrets 180 to 250, with small complexes in rabbits (R wave up to about 0.4 mV) and tall ones in ferrets (up to about 3 mV). Their normal values come from small studies, so treat a borderline result as normal unless the patient has signs.
At 50 mm/s one small box is 20 ms and one big box is 100 ms. At 25 mm/s they are 40 and 200 ms. At the standard sensitivity, 10 mm is 1 mV. The QT shortens as the heart speeds up, so for dogs the helper also gives a corrected QT using QT minus 0.087 times (R to R in ms minus 1000). With a rate entered it judges a dog's QT on that corrected value: long over about 280 ms, a guide from healthy beagles (245 plus or minus 18 ms). With no rate, 150 to 250 ms applies at a normal heart rate.
Naming the rhythm
| You see | Likely rhythm |
|---|---|
| Wide, fast, no P wave leading each beat | Ventricular tachycardia |
| Wide, near-normal rate, regular | Accelerated idioventricular rhythm |
| Wide, slow, regular | Ventricular escape rhythm. Do not suppress |
| Wide, chaotic, no P waves | Atrial fibrillation with a wide QRS, or a ventricular rhythm of changing shape |
| No P waves, chaotic | Atrial fibrillation |
| No P waves, slow | Atrial standstill. Check potassium |
| Narrow, fast, regular, P hidden | Supraventricular tachycardia |
| More P waves than QRS, PR lengthening | Second-degree block, type I |
| More P waves than QRS, no warning | Second-degree block, type II |
| P waves and QRS unrelated, slow QRS rate | Third-degree block |
| P waves unrelated to a fast QRS | AV dissociation, not heart block |
| Rate rises and falls with breathing | Sinus arrhythmia. Normal in dogs |
Movement, purring, panting and shivering imitate arrhythmias. Feel the pulse while you watch the trace.
How to read the drawings
Every drawing is a short lead II trace on ECG paper with numbered purple pins. Each pin marks one thing to look for, and the same number appears in the list under the drawing. A list item marked (not drawn) has no pin. A pin on a line points at a wave. A pin on a bar marks a gap or an interval. The drawings are made by the helper to show the pattern clearly. They are not recordings, so compare the shape and the spacing with your strip and ignore the size.
| Condition | Changes drawn |
|---|---|
| High potassium | Tall T, flat P, no P with wide QRS, sine wave |
| GDV and splenic disease | Single wide beats, steady wide rhythm, runs, R on T |
| Fluid around the heart | Alternating R height, small complexes, fast rate, ST raised |
| Mitral valve disease | Wide P, tall R, early narrow beats, atrial fibrillation |
| Dilated cardiomyopathy | Atrial fibrillation, wide early beats, runs, tall QRS |
| Cat with thick heart muscle | Deep S with left axis, tall R, wide early beats, atrial fibrillation |
| Small breed that faints | Fast bursts then a pause, long pauses, slow rate, junctional beats |
| Low calcium and low potassium | Long QT, flat T with an extra bump |
| Digoxin toxicity | Long PR, dropped beats, bigeminy, sagging ST |
Electrical axis
The axis is the average direction of the QRS in the frontal plane. Take the net height of the QRS in lead I and in aVF (tallest wave above the line minus deepest wave below it) and the angle is the arctangent of 1.155 times aVF over lead I. Normal is +40 to +100 degrees in dogs and 0 to +160 in cats. A shift to the right points to right ventricular enlargement or right bundle branch block. A shift to the left points to left ventricular enlargement or a block in the front branch of the left bundle, the classic finding in cats with thickened heart muscle.
Wide and fast: when to treat
Treat when the rate is over 180 in a dog or 240 in a cat (sources put the cat line between 220 and 250), the pulses are weak, early beats land on the T wave before, the wide beats have more than one shape, or, in a dog, runs over 30 seconds go above 160. Otherwise fix the cause: pain, low oxygen, low blood volume, potassium and magnesium. Dogs get lidocaine 2 mg/kg into the vein, repeated to 8 mg/kg in total (counting any lidocaine given for blocks that day), then an infusion at 25 to 80 micrograms/kg/min. Cats get 0.25 to 0.4 mg/kg slowly, once or twice, then an infusion of 10 to 20 micrograms/kg/min, because they seizure easily. A wide rhythm under 120 in a dog or 140 in a cat is treated as an escape rhythm, and the helper hides every suppressing drug.
In 49 Boxers with more than 500 ventricular beats a day, sotalol, or mexiletine with atenolol, reduced the count and the severity. Atenolol alone and procainamide alone did not.
Atrial fibrillation: rate control
In a randomised crossover trial of 18 dogs with fast atrial fibrillation, the 24-hour average rate fell from 194 to 126 on diltiazem with digoxin, compared with 158 on diltiazem alone and 164 on digoxin alone. In a separate study of 46 dogs, a 24-hour average under 125 went with a median survival of 1,037 days against 105 days at 125 or over. The helper gives the pair by default, leaves digoxin out when creatinine is raised, caps it at 0.25 mg a dose, and leaves out esmolol when heart failure or low blood pressure is ticked.
Slow rhythms and pacemakers
First rule out high potassium and drugs. Then run an atropine test: 0.04 mg/kg, with a repeat ECG at 15 to 30 minutes. A pass is a regular sinus rhythm at 140 or more in a dog with the block gone, which points to vagal tone. A fail points to disease of the conduction system. Atropine is hidden when dexmedetomidine or medetomidine is on board: reverse the drug. Under anaesthetic or on an opioid the test is left out, and atropine 0.02 to 0.04 mg/kg is given only for a low blood pressure. In third-degree block most patients do not respond to the test.
Third-degree block and sick sinus syndrome with fainting need a pacemaker. In 154 paced dogs, 59% had third-degree block and 29% had sinus node disease. Survival was 70% at 1 year, 57% at 2 and 45% at 3, with a major complication in a third. In a later series of 49 dogs with high-grade block, median survival after pacing was 24.5 months.
Reading a 24-hour recording
| Ventricular beats in 24 hours | Any dog or cat | Boxer | Dobermann |
|---|---|---|---|
| Under 50 | Normal | Normal | Normal |
| 50 to 300 | Cats: abnormal. Other dogs: abnormal over 100 | Uncertain to suspicious | Suspicious: repeat within a year |
| Over 300 | Abnormal | Likely affected | Affected: treat |
| Over 1,000, pairs or runs | Treat | ||
Counts can swing by up to 80% with no treatment in Boxers with frequent beats, and by almost 100% when counts are lower (Spier and Meurs 2004), so a drug is only credited with a fall of 85% or more. Pauses over 6 seconds in a dog, or 3 in a cat, are long. Healthy older cats can have up to about 150 single beats a day. Always read the count against the diary. The Boxer bands come from Boxer studies (the ARCH 2009 scheme, Meurs 2014) and are also used for English Bulldogs.
Anaesthesia, pacemakers, drugs and poisons
Under anaesthetic, fix oxygen, carbon dioxide, depth and temperature before reaching for a drug. A slow rate on dexmedetomidine with a good blood pressure is expected and is left alone. Pacemakers: a spike with no beat after it is loss of capture, usually a moved lead. Pauses with no spike mean the device is not firing. Both need a cardiologist the same day. Drugs: sotalol and tricyclics lengthen the QT, digoxin can cause any arrhythmia, and alpha-2 drugs cause slow rates and block. Poisons: chocolate and asthma inhalers cause fast rates that answer to propranolol. Oleander-type plants act like a digoxin overdose. Toads cause fast or slow rhythms, most often ventricular tachycardia. Tricyclics widen the QRS and answer to sodium bicarbonate.
Drugs the helper holds back
- Escape rhythm or heart block with wide beats: no lidocaine, procainamide or sotalol.
- Long QT: no sotalol or procainamide. Magnesium first.
- Wide, very fast atrial fibrillation: no diltiazem, digoxin or beta blocker.
- Heart failure or poor contraction: no sotalol, atenolol or esmolol.
- Alpha-2 drug on board: no atropine.
- Cats: no mexiletine, and digoxin only on a cardiologist's advice.
- Kidney disease: magnesium, sotalol and cat atenolol halved, dog atenolol at the lower range, no digoxin, procainamide at the low end.
Potassium, calcium and the trace
Rising potassium classically gives tall pointed T waves, a longer PR, flat then absent P waves, a wide QRS and finally a sine wave. Patients skip steps, and a trace can look normal with a potassium of 8, so measure it. Low calcium and low potassium lengthen the QT. High calcium shortens it.
Common questions
Which paper speed should I use?
50 mm/s for measuring and for fast rhythms, because the waves are spread out. 25 mm/s for a long rhythm strip.
The rhythm is irregular. How do I get a rate?
Count the beats in 6 seconds and multiply by 10. That is 300 mm of paper at 50 mm/s or 150 mm at 25 mm/s.
How do I tell ventricular tachycardia from a fast rhythm with a bundle branch block?
Look for a P wave in front of every wide beat. If each has one at a fixed distance, the rhythm starts above the ventricles. If you cannot tell and the patient is unstable, treat as ventricular.
There are ventricular beats after a GDV. Do I treat?
Not for the beats alone. Treat for a rate over 180, runs over 30 seconds above 160, poor pulses, R on T or several shapes. Correct potassium and magnesium first.
The anaesthetised dog is at 45 on dexmedetomidine. Atropine?
No. Check the blood pressure. If it is normal or high, leave it. If it is low, reverse the dexmedetomidine.
Is it a faint or a fit?
A faint is sudden, limp and brief, often set off by exercise or excitement, with instant recovery. A seizure usually starts at rest, involves paddling or chewing, lasts longer and leaves the patient confused. The "Faint or fit?" tool scores both.
The trace is too messy to read. What do I do?
Re-wet the clips, move them down the legs, stop any purring or shivering, and unplug nearby clippers and heat pads. Real beats march through the mess at the patient's own rate and have a P-QRS-T shape with a T wave. Early beats often have no pulse (a pulse deficit), so a missing pulse does not make it artefact. Check a second lead: a real beat shows in every lead.
Can an ECG tell me the heart is enlarged?
It can suggest it, with a wide P wave or a tall R wave, but it misses most cases. Use an x-ray or ultrasound.
Sources
ASK A VET™ · ECG Helper · By Dr Duncan Houston · Talk. Track. Trust.
Ask A Vet’s vet support lives in the app. See the app
This tool remembers your settings in this browser only — units, sounds and the like. No patient details are saved. It is never sent to Ask A Vet.